Dolphin XP-005 Probe & Cutter Abnormal Conductivity Self-Inspection

Key Cutting Machine

How to do in case Xhorse Dolphin XP-005 occurs an “ERROR CODE:57, Probe short circuit, please check probe electrical conductivity”? After clearing probes and doing self-test in Electrical Conductivity Measurement, this problem may be solved. If unfortunately, all that do not work, you’ll have to detect probe & milling cutter abnormal conductivity by yourself.

Dolphin Xp 005 Probe Cutter Abnormal Conductivity Self Inspection (1)

Method
1. Separating the rear cover, be careful of the wiring harness when operating.

Dolphin Xp 005 Probe Cutter Abnormal Conductivity Self Inspection (2)

2. Remove wire harness Phillips screws(pic3). Remove rubber pellets to take out screws inside. Remove the long strip with a HEX screwdriver.(pic4).

Dolphin Xp 005 Probe Cutter Abnormal Conductivity Self Inspection (3)

Dolphin Xp 005 Probe Cutter Abnormal Conductivity Self Inspection (4)

3. Rotate the lead screw with a flat-blade screwdriver. Align Z-axis as the cover in same horizontal line(pic5-6). Remove Z-axis housing after alignment, install the probe next to it(pic6). Remove screws in (pic7).
Note: please be careful of a conductive wire inside probe(pic8).

Dolphin Xp 005 Probe Cutter Abnormal Conductivity Self Inspection (5)

Dolphin Xp 005 Probe Cutter Abnormal Conductivity Self Inspection (6)

Dolphin Xp 005 Probe Cutter Abnormal Conductivity Self Inspection (7)

Dolphin Xp 005 Probe Cutter Abnormal Conductivity Self Inspection (8)

4. Inspect whether the wires of probe & milling cutter are conductive or short. Please connect with main board for detection(pic9). Plug in main board cable for detection is also workable.

Dolphin Xp 005 Probe Cutter Abnormal Conductivity Self Inspection (9)

5. Loosen and tighten Z-axis screws(pic10). Push the 2 screws to inside until there is a gap. That’s for getting out a shaft. Press on the milling cutter hole position, push it up then observe the white paper inside is broken or not(pic11).
If it was broken, it needs to be replaced;
If it was not broken, observe if there’s iron scraps in the bearing hole.

Dolphin Xp 005 Probe Cutter Abnormal Conductivity Self Inspection (10)

Dolphin Xp 005 Probe Cutter Abnormal Conductivity Self Inspection (11)

Hope this is helpful.

This is Dolphin XP-005 manual guide to self-check abnormal conductivity of probe & milling cutter. More any questions feel free to contact us.
www.xhorse.co.uk